When Problems Occur: Lessons in Spectroscopy, Setbacks and Better Solutions
Upon joining the BHP research laboratories as a graduate, I was given the choice of being in charge of instrumental analysis by XRF (X-Ray Fluorescence) or OES (Optical Emission Spectroscopy). Both were used for comprehensive simultaneous analysis of research samples. Having earlier worked with spectroscopy, I chose OES. This was a vacuum Jarrell-Ash model designed mainly for steel samples as the vacuum optical range was limited to the UV, going from 400 to 190 nm. The curved reflection grating focussed its first order to an arc about a meter long. Typically 40 exit slits were accurately located for emission lines for elements of interest and illuminated any of 20 photomultiplier (PM) tubes for simultaneously analysis. Some of these exit slits and PM tubes could only be accessed in the vacuum section below 220 nm. This optical range excluded optimum alkali emission lines and including some that had limited sensitivity by XRF. The interface to the vacuum portion had the additional disadvantage that the most favourable zinc emission line was also excluded. Items had already been ordered to upgrade the OES improve sensitivity for alkali analysis.
The approved approach was to attach a secondary Varian grating spectrometer to the back of the Jarrell-Ash by reflecting its zero-order light through a quartz window cut into the back of the vacuum tank (see figure). To ensure best sensitivity, the Varian spectrometer was ordered with its grating blazed for the visible range and the photomultiplier (PM) selected had top-of-the-range sensitivity in the visible region with especially low background. Our head of the department was fastidious in selecting items for optimum performance and before installation, he insisted we confirm the correct blaze angle for the optical region was included. To do this it was necessary to swap and compare the Varian spectrometer with one already used for Atomic Absorption (AA) where its blaze angle was set for the mid UV range. It came as a surprise that the new spectrometer was significantly poorer in sensitivity in the visible range when compared with the AA one. Varian had supplied a grating that was blazed for the far UV and required replacement. This pre-checking of items ordered was an important lesson in itself. Instruments purchased were always only chosen after acceptable test results were provided from typical samples supplied. Twenty years later when teaching at University, this approach of prior testing supplied samples avoided choosing an inferior high pressure liquid chromatograph.
Getting results for the modified OES was significantly delayed to the correct grating came. In the meantime, a proposed conference paper was submitted before the deadline and accepted for a spectroscopy conference in Canberra later that same year.
The elaborated mounting for the Varian spectrometer with focussing lenses had been specially manufactured in-house to accept the reflected zero order Jarrell-Ash light and the sensitive PM in the Varian spectrometer was plugged into one of the 20 Jarrell-Ash inputs. Results obtained for sodium analysis were just measurable with wide slit openings on the Varian spectrometer and the PM increased to maximum input voltage. The whole modification was near a total failure as it would not be adequate for any less sensitive lines. Had the blaze for the Varian grating not been replaced, even sodium analysis would not have been possible. The secondary purpose for the modification was to easily check out other UV lines for widening the Jarrell-Ash analytical capability. Its main frame had fixed exit slits for each element selected, but alterations to the main frame was a major undertaking. Checking other lines first via the Varian Spectrometer to verify if suitable for main frame alterations was not possible with such low light levels.
What to do about the conference presentation already accepted?
For this I chose to present only one slide (see figure) and explained the other objectives in a short presentation. Many spectroscopists were in attendance and my talk had been set last in a long day. When I requested suggestions, it revived all present, one comment noted that most of the light to modern gratings were dispersed into the 1st and 2nd order with little just reflected to the zero order, which confirmed the low sensitivity. Max Amos proposed rather than attempting to use the zero order, he suggested going back to collect light direct from the spark source using a fibre optic bundle and feed light direct to the Varian spectrometer. The session ended with all participants much more alert and ready for the evening meal. I learnt an important lesson about the value of being open in a conference setting, not to be unduly concerned by poor findings, but listen to the expertise of the audience so one can move forward. Modifications were made using a fibre bundle and this gave light levels typically six orders of magnitude higher. All findings were later published (see references).
Twenty years on, at a similar conference at Monash University, again I had been allotted to speak last for the day. This time, the program timetable listings was unclear, in my session there were three other speakers each given 15 minutes, but for my presentation it gave only the starting time. Mine needed setting up for a demonstration of a low-cost 3 way teaching spectrometer (colorimetric, emission and AA) with computer output that we had developed. The chairperson advised each of the others were plenary speakers whereas my presentation although not specified, was to be limited to 5 minutes. The late notice for the shorter time came as a surprise, but having by now taught in tertiary education for more than 15 years, it was easy enough to just quickly demonstrate snippets of the key cost saving advances for teaching. Again, the audience’s attention became visibly inspired and they were uplifted before the meal that followed. This latter teaching equipment was manufactured and marketed by IEC P/L in Thornbury (Vic) (see their catalogue cover) and outcomes later published by RACI. Over 100 units were sold mainly to Victorian Secondary Schools.
References
- R J Hodges and C B Belcher, "Alkali Analysis Using Light Reflected from the Grating of an Optical Emission Spectrometer", Applied Spectroscopy, 1975, 29, 163-167.
- J C Mills and R J Hodges, "Fibre Optics Expand the Range of a Direct-Reading Spark Optical Emission Spectrometer", Applied Spectroscopy, 1984, 38(3), 413-6.
- R Hodges, “Low-cost teaching instrumentation for chemical analysis”, Chemistry in Australia, September 2005, 72 (8), 3-6.
|
|
Dr Ray Hodges FRACI (retired Associate Professor from Monash Gippsland)
|